Composite cable heat tracing pipe

Introduction of heat tracing sampling composite pipe and cable

Heat tracing sampling composite pipe and cable is an important component in the monitoring system. It is composed of a group of corrosion-resistant high-performance resin conduit, high-temperature constant power electric heating belt or self limiting electric heating belt and compensation cable. It is added with imported raw material insulation layer and coated with polyethylene or polyvinyl chloride sheath after z.ui. The constant power electric heating band adopts platinum resistance temperature probe to control the temperature. The automatic temperature limiting function of self temperature limiting electric heating band can ensure that a certain temperature is maintained in the sampling tube, so as to ensure that the collected samples are consistent with the initial value as much as possible, and z.ui finally ensures the continuity of the monitoring system. Accurately collect the sample gas. According to different ambient temperatures, appropriate tracking belt, compensation line, power line, etc. can be used. It can also be added according to user requirements.

Technical parameters of heat tracing sampling composite pipe and cable

1. Supporting heat pipe: made of perfluorooctane sulfonic acid, FEP and polytetrafluoroethylene;; The outer diameter is 6mm, 8mm and 10mm, with single pipe, double pipe and three cores.

2. Companion belt: Mi heating cable, constant power and automatic temperature control.

3. Outer diameter of heat tracing pipe: DN32 2 mm, dn38 2 mm, dn42 2 mm, dn45 2 mm

4. The heat tracing temperature of sampling gas is 70 ℃ / 85 ℃ / 100 ℃ / 120 ℃ / 150 ℃ / 180 ℃ / 220 ℃.

5. Insulation layer: high temperature resistant rock wool and glass wool.

6. Sheath layer: Black polyvinyl chloride / polyvinyl chloride / polyethylene wear-resistant layer, flame retardant / waterproof / high temperature / corrosion resistant.

Installation rules of heat tracing sampling composite pipe

Electrical index

1. Rated voltage: 220VAC

2. The self temperature limiting pipeline z.ui has a large heating length of 100 ~ 120m

3. The self temperature limiting pipeline is equipped with a circuit breaker with a current value of 30a

4. One circuit of heat tracing system.

Thermal index

1. Under the condition of – 20 ℃ ambient temperature and 15m / s wind speed, the temperature in the pipe shall be maintained at 40 ~ 50 ℃.

2. The sampling tube can resist the corrosion of various acid and alkali media, and the compressive strength is 1.0MPa without leakage.

3. The sampling tube can work for a long time at a temperature of < 200 ℃.

Installation index

1. The z.ui small curvature radius of the composite pipe is 0.5m.

2. Z.ui low installation temperature – 20 ℃ (take appropriate measures at – 30 ℃ ~ – 40 ℃).

3.z.ui small fixed distance: 2m vertically and 4m horizontally.

Precautions for installation of heat tracing sampling composite pipe

It is strictly prohibited to twist and drag on the ground during construction. The pipe head sheath can be removed only after the contact is installed. The end of the tracing band shall be closed to prevent short circuit of two wires of the tracing band and burning of the tracing band. The shielding layer of the tracing band must be grounded to prevent electric shock. Special intermediate junction box or power junction box shall be used at one end of the power supply to avoid potential accidents. Install leakage protector of distribution switch.

Products

Discover Related products

Our products are widely used and provide one-stop solutions

Heating cable

Heating cable

Heating cable

Mi heating cable

Heating cable

Constant power series electric heater

Heating cable

Constant power parallel connection with tracing belt

Heating cable

Self limiting temperature low temperature with tropical zone

Heating cable

Self-limiting medium temperature tracing belt

Heating cable

Self-limiting high temperature tracing belt

Compensation conductor

KC compensating conductor

Compensation conductor

K type compensation conductor

Compensation conductor

High temperature resistance compensation wire

Compensation conductor

B type compensation conductor

Compensation conductor

Multiple compensating conductor

Compensation conductor

CS compensation cable

Compensation conductor

Intrinsically safe high temperature compensation cable

Compensation conductor

T type compensation wire

Silicone rubber cable

Silicon rubber high temperature power cable

Silicone rubber cable

Silicone rubber high temperature control cable

Silicone rubber cable

ZR-YGC flame retardant silicone rubber cable

Silicone rubber cable

YGCRP silicone rubber flexible cable

Silicone rubber cable

YGCP silicone rubber shielded cable

Silicone rubber cable

YGCR silicone rubber cable

Silicone rubber cable

Silicon rubber flat cable

Silicone rubber cable

Silicone rubber high temperature cable

Silicone rubber cable

Silicone rubber cable

Flat cable

Special high temperature and high voltage resistant flat cable

Flat cable

YFFB flat cable

Flat cable

Double wire flat cable

Flat cable

YGFB flat cable

Flat cable

Running flat cable

Flat cable

Crane power flat cable

Flat cable

TVVB elevator flat cable

Flat cable

YZB medium flat rubber sheathed cable

Flat cable

YFFB/G multi-core flat cable

Special cable

Cable for BPGGP converter

Special cable

High temperature and oil resistant special cable

Special cable

Offshore oil platform explosion-proof cable

Special cable

Nuclear power plants use K3 type cables

Special cable

Marine radio frequency cable

Special cable

Low smoke halogen free cable

Special cable

Special refractory cable

This website uses cookies to improve your web experience.
Explore
Drag